EUD-2016026-00 Rev.2, SmartScanIS User’s Guide for Union Pacific, 14 January 2021
175
9
If the Hotbox alarm is announced for the wrong side, switch the bearing scanner
connections on the Scanner Interface board.
Plug the connector from the bearing scanner on rail1 (that is, from the north or east
rail) into the first (top) box connector on the Scanner Interface board. Plug the
connector from the bearing scanner on rail2 (that is, from the south or west rail) into the
second box connector on the Scanner Interface board.
10
Repeat the test, this time placing the calibrated heat source on the bearing scanner on
the opposite rail.
11
Verify the results as before.
If the results are correct, your system should function properly when scanning the
bearings of real trains.
12
Remove the calibrated heat source.
13
If this is a double-track site, repeat steps
1
through
12
for the other track (that is, for the
other SmartScanIS).
14
Store the calibrated heat source and its cable in the bungalow.
9.12 Checking Communication with Harriman Dispatch Center
To check communication with the Harriman Dispatch Center:
1
Using the serial interface, display the Main menu.
Chapter 11 - Serial Interface
tells how to display the Main menu.
2
Select
Setup Menu
.
3
At the password prompt, type
uptest
Bearing
Scanner
Connectors
Rail1
Rail2
Bearing
Scanner
Connectors
Bearing
Scanner
Connectors
Rail1
Rail2
Rail1
Rail2
Содержание SmartScanIS
Страница 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Страница 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...