Using the three-position side-selection switch, select the side of the car on which the
alarm is to be generated.
Either side can be picked for either alarm. If you want side one (that is, the north or
east rail), move the switch up. If you want side two (that is, the south or west rail),
move the switch down.
After the switch is pressed, the panel is armed and the LED labeled
ARM
lights. The
panel stays armed until the next train exits or until you manually disarm the panel.
14.2 Disarming the Efficiency Test Panel
As long as the LED labeled
ARM
(on the Efficiency Test panel) is lit, the Efficiency Test panel
is armed. While armed, changing the wheels or switches doesn't change the settings. The
only way to change the settings is to disarm the panel first. For example, if you armed the
panel with car number set to 23, the only way to change it to 27 is to disarm the panel first.
Or, if you armed the panel with type of alarm set to DED, the only way to change it to HBD is
to disarm the panel first.
To disarm the Efficiency Test panel:
1
Using the thumbwheels, select 00.
2
Using the three-way side-selection switch, select either side.
The LED labeled
ARM
ceases to be lit.
Содержание SmartScanIS
Страница 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Страница 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...