Chapter 14
Using the Efficiency Test Panel
This chapter tells how to arm and disarm the Efficiency Test panel.
The figure below shows the part of the Efficiency Test panel that is used for arming and
disarming the panel.
14.1 Arming the Efficiency Test Panel
To arm the Efficiency Test panel:
1
Using the thumbwheels, select the number of the car on which the alarm is to be
generated.
Pick a number from 01 through 99. When that car is sensed, an alarm (on the first axle
of that car) is generated. If that car isn't reached, no alarm is generated and the panel
is disarmed at train exit.
2
Using the two-position detector-selection switch, select the type of alarm you want to
be generated.
If you want an absolute Hotbox alarm, toggle HBD. If you want a Dragging-Equipment
alarm, toggle DED. If DED is selected, the appropriate alarm is generated only when
the
Dragger option
on the Equipment submenu is enabled.
NORMAL
SIDE 1
SIDE 2
RADIO TEST
DED
HBD
CAR #
ARM
EFFICIENCY
PANEL
TEST
Содержание SmartScanIS
Страница 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Страница 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...