Heading
Contents of Field
AC Surge
Suppressor
The AC surge suppressor status. When the firmware detects a properly
operating surge suppressor, the message "AC Surge Suppressor:OK"
appears. When something occurs to blow the surge suppressor, the
message "AC Surge Suppressor:Blown
mm/dd/yyyy hh:mm
" appears,
showing the date/time that the failure occurred. For instance, a surge
suppressor failure occurring at 12:34 on 27 October 2012, gives an "AC
Surge Suppressor:Blown 10/27/2012 12:34" message.
Alarm Limits
The alarm parameters and limits as they are currently defined in the system
setup. You change these parameters and limits using the Alarm Limits
submenu.
Chapter 11 - Serial Interface
tells how to set these values.
Equipment
Equipment configuration as currently defined in the system setup. You
change this configuration using the Equipment submenu.
Chapter 11 -
Serial Interface
tells how to set these values.
Messages
Message configuration as currently defined in the system setup. You
change this configuration using the Messages submenu.
Chapter 11 - Serial
Interface
tells how to set these values.
Polling System Polling system configuration as currently defined in the system setup. You
change this configuration using the Polling System submenu. Information
dealing with the wind monitor and the rail-stress monitor is also displayed
here.
Modem Setup
The active modem configuration commands and which modem (default or
alternate) is currently selected. You change this configuration using the
Modem Setup submenu.
Chapter 11 - Serial Interface
tells how to set these
values.
Serial Ports
Communications port configurations, for COM1, COM2, and COM3, as
currently defined in the system setup. You change this configuration using
the Serial Ports submenu.
Amtech
Reader
Parameters
This heading always appears, even if the AEI subsystem is disabled using
the
AEI option
on the Equipment submenu. After Reader1 can be either
AI1200 or None. (In this case, AI1200 means the 2200-750 Reader.) After
Reader2 is only None.
Below are the AEI Reader Parameters currently defined in the system setup.
These values were in place at the time this report was run.
ID Separation specifies the number of intervening tags that must be
read and reported before a given tag is reported again. Valid values
are 1, 2, 3, and 4. The default is 2.
Consecutive Reads specifies the number of times that a tag must be
read before it is considered a valid (reportable) tag. Valid values are
1, 2, 3, and 4. The default is 2.
Uniqueness Timeout specifies the number of seconds that the ID
Separation parameter is in effect for a given tag. When a 2200-750
Reader is attached to the system, the Uniqueness Timeout
parameter is automatically set to 120 seconds. For a 2200-750
Reader, this value cannot be changed.
Chapter 11 - Serial Interface
tells how to set these values using the Amtech
Reader Parameters submenu.
Содержание SmartScanIS
Страница 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Страница 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...