136
14 January 2021, SmartScanIS User’s Guide for Union Pacific, EUD-2016026-00 Rev.2
Observe correct polarity
when you connect the wires from the transducers. The polarity is
correct when the transducer's white wire is connected directly under the existing white wire at
row two of the UTB, and the transducer's black wire is connected directly under the existing
black wire at row two of the UTB. Connect
TO1
first and
TO2
second.
TO1
is the gating
transducer closest to the bearing scanner.
TO2
is the one farthest from the bearing scanner.
White Wire from Gating Transducer
Black Wire from Gating Transducer
White Wire from System Interface Board
Black Wire from System Interface Board
White Wire from Gating Transducer
Black Wire from Gating Transducer
White Wire from System Interface Board
Black Wire from System Interface Board