228
14 January 2021, SmartScanIS User’s Guide for Union Pacific, EUD-2016026-00 Rev.2
11.3.6 Messages
To set or change one or more of the message parameters:
1
Be sure that the Setup menu is displayed.
The top part of the Setup menu looks like this.
STC Integrated Detector System, Milepost-0501.2, Track:Single
05/31/2013
9:35
Setup Menu
------------------------------------------------
A) Set Date and Time
B) Milepost
C) Track Number
D) Alarm Limits
E) Equipment
F) Messages
G) -For Future Use-
•
•
2
Select the
Messages
submenu.
A menu and prompt like this appears. The options on the Messages submenu are
used to affect the phrases broadcast to a passing train.
Milepost-0125.0, Track:3
Messages
-----------------------------------------------------
A) Axles....................... YES
B) Arrival..................... YES
C) Speed....................... YES
D) Length...................... YES
E) Temperature................. YES
F) Power Off................... YES
G) HiWide...................... YES
H) Car ID...................... YES
I) No Defects.................... 1
J) Rebroadcast Time Limit.
10 min.
Message to change or Esc to quit?
3
To leave the Messages submenu and return to the Setup menu:
a
Press
[Esc]
.
The Setup menu reappears.
b
Skip the remaining steps.
Содержание SmartScanIS
Страница 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Страница 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...