EUD-2016026-00 Rev.2, SmartScanIS User’s Guide for Union Pacific, 14 January 2021
223
13
To set or change the
gate distance
(aka gate width) value:
The Equipment submenu shows the number of inches between the centers of the
gating transducers.
•
•
•
I) Sliding Wheel............... YES
J) Gate Distance....... 24.0 inches
K) Cold Wheel.................. YES
L) Resistor Integ. Test.... Enabled
M) Modem Type:.............. Analog
N) Min. Transducer Pulse Width. 3mS
O) Cold Rail Test....... All Trains
Equipment to change or Esc to quit?
a
From the Equipment submenu, select
Gate Distance
.
This prompt appears.
Gate Distance:
The format for gate width (gate distance) is
nn.n
. If the new value has less than
three digits, type leading zeros, trailing zeros, or both. Thus, for 2, type
020
. The
system inserts the decimal point for you. The gate width (it is usually 24.0) can be
recorded in 1/10-inch increments to reflect the actual transducer spacing. Accurate
gating-transducer spacing results in accurate speed calculations.
b
Enter the three-digit number.
The
Gate Width option
on the Equipment submenu changes. The Equipment
submenu reappears.
c
Return to step
3
.
Содержание SmartScanIS
Страница 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Страница 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...