249
b
If you want to disable the primary telephone number, select
Primary Phone#
and
then press
[Enter]
.
c
If you want to change the secondary telephone number, select
Secondary Phone#
and then type in the desired phone number.
d
If you want to disable the secondary telephone number, select
Secondary Phone#
and then press
[Enter]
.
e
Go to step
7
.
6
If you selected Poll/Standalone mode:
a
If you want to change the
Poll Address
select the
Poll Address
option and then
type in a letter.
Poll/Standalone mode lets you select an address letter. Any letter may be typed. If
you don't input a poll address, it defaults to the letter
A
.
b
If you want to change the
RFL Delay
, select the
Poll Delay
option and then type in
a number from 200 through 500.
The number after the words RFL Delay is the amount of delay, in milliseconds,
between the system keying of the polling-system radio and the time that the radio is
ready to accurately transmit data. If you don't input a value for the RFL delay, it
defaults to 200 milliseconds.
7
If you want to change the
Site ID
, select the
Site ID
option and then type in six or less
digits, letters, or both digits and letters.
If you don't input a value for site name, it defaults to
NONAME
.
8
If you want to change the
Calibration Temp
, select the
Calibration Temp
option and
then type in a number from 100 through 250.
This option lets you enter the calibration temperature in degrees Fahrenheit. Once
entered, this value is used for display purposes only. It is not an alarm limit. (This
parameter defaults to 180.)
9
If you want to disable/enable the
Wind Monitor
This option shows whether the wind-monitor feature is enabled (YES) or disabled (NO).
It doesn't show whether the wind-monitor hardware was installed or not. Selecting the
Wind Monitor
option toggles enabled and disabled.
10
If you want to change the
High Wind Alarm
limit, select the
High Wind Alarm
option
and then type in a number from 30 through 100.
This option lets you enter a wind speed in miles per hour. When the wind monitor
records a wind speed that matches or exceeds this alarm limit, the detector flags a high
wind condition and queues a WX message for transmission to the Harriman Dispatch
Center. (This parameter defaults to 50.)
11
To leave the Polling System submenu and return to the Setup menu, press
[Esc]
.
The Setup menu reappears.
Содержание SmartScanIS
Страница 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Страница 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...