Table 17.6. 0x0006–0x0008 TOOL_VERSION
Reg Address
Bit Field
Type
Name
Description
0x0006
3:0
R/W
TOOL_VERSION[3:0]
Special
0x0006
7:4
R/W
TOOL_VERSION[7:4]
Revision
0x0007
7:0
R/W
TOOL_VERSION[15:8]
Minor[7:0]
0x0008
0
R/W
TOOL_VERSION[15:8]
Minor[8]
0x0008
4:1
R/W
TOOL_VERSION[16]
Major
0x0008
7:5
R/W
TOOL_VERSION[13:17]
Tool. 0 for ClockBuilder Pro
Table 17.7. 0x0009–0x000A NVM Identifier, Pkg ID
Reg Address
Bit Field
Type
Setting Name
Description
0x0009
7:0
R
TEMP_GRADE
Device temperature grading
0 = Industrial (–40 °C to 85 °C) ambient conditions
0x000A
7:0
R
PKG_ID
Package ID
0 = 9x9 mm 64 QFN
Part numbers are of the form:
Si<Part Num Base><Grade>-<Device Revision><OPN ID>-<Temp Grade><Package ID>
Examples:
Si5396C-A12345-GM.
Applies to a “base” or “blank” OPN (Ordering Part Number) device. These devices are factory pre-programmed with the frequency plan
and all other operating characteristics defined by the user’s ClockBuilder Pro project file.
Si5396C-A-GM.
Applies to a “base” or “non-custom” OPN device. Base devices are factory pre-programmed to a specific base part type (e.g., Si5396
but exclude any user-defined frequency plan or other user-defined operating characteristics selected in ClockBuilder Pro.
Table 17.8. 0x000B I2C Address
Reg Address
Bit Field
Type
Setting Name
Description
0x000B
6:0
R/W
I2C_ADDR
7-bit I2C Address. Note: This register is not bank burna-
ble.
Table 17.9. 0x000C Internal Fault Bits
Reg Address
Bit Field
Type
Setting Name
Description
0x000C
0
R
SYSINCAL
1 if the device is calibrating.
0x000C
1
R
LOSXAXB
1 if there is no signal at the XAXB pins.
0x000C
2
R
LOSREF
1 if no signal is detected on the XAXB pins.
0x000C
3
R
XAXB_ERR
1 if there is a problem locking to the XAXB input signal.
0x000C
5
R
SMBUS_TIMEOUT 1 if there is an SMBus timeout error.
Si5397/96 Reference Manual
Si5396 Register Map
silabs.com
| Building a more connected world.
Rev. 0.9 | 262