Table 15.225. 0x0632-0x0634
Reg Address
Bit Field
Type
Setting Name
Description
0x0632
7:0
R/W
HOLD_15M_CYC_
COUNT_PLLC
Set by CBPro.
0x0633
15:8
R/W
HOLD_15M_CYC_
COUNT_PLLC
0x0634
23:16
R/W
HOLD_15M_CYC_
COUNT_PLLC
Table 15.226. 0x0635 DSPLL C Force Holdover
Reg Address
Bit Field
Type
Setting Name
Description
0x0635
0
R/W
FORCE_HOLD_PL
LC
0: For normal operation
1: To force holdover
Table 15.227. 0x0636 DSPLLC Input Clock Switching Control
Reg Address
Bit Field
Type
Setting Name
Description
0x0636
1:0
R/W
CLK_SWITCH_MO
DE_PLLC
Clock Selection Mode
0: Manual
1: Automatic, non-revertive
2: Automatic, revertive
3: Reserved
0x0636
2
R/W
HSW_EN_PLLC
0: Glitchless switching mode (phase buildout turned off)
1: Hitless switching mode (phase buildout turned on)
Table 15.228. 0x0637 DSPLLC Input Alarm Masks
Reg Address
Bit Field
Type
Setting Name
Description
0x0637
3:0
R/W
IN_LOS_MSK_PLL
C
For each clock input LOS alarm
0: To use LOS in the clock selection logic
1: To mask LOS from the clock selection logic
0x0637
7:4
R/W
IN_OOF_MSK_PLL
C
For each clock input OOF alarm
0: To use OOF in the clock selection logic
1: To mask OOF from the clock selection logic
For each of the four clock inputs the OOF and or the LOS alarms can be used for the clock selection logic or they can be masked from
it. Note that the clock selection logic can affect entry into holdover.
IN0 Input 0 applies to LOS alarm 0x0637[0], OOF alarm 0x0637[4]
IN1 Input 1 applies to LOS alarm 0x0637[1], OOF alarm 0x0637[5]
IN2 Input 2 applies to LOS alarm 0x0637[2], OOF alarm 0x0637[6]
IN3 Input 3 applies to LOS alarm 0x0637[3], OOF alarm 0x0637[7]
Si5397/96 Reference Manual
Si5397A/B Register Map
silabs.com
| Building a more connected world.
Rev. 0.9 | 154