ClockBuilder Pro handles these bits when changing settings for all portions of the device. This control bit is only needed when changing
the settings for only a portion of the device while the remaining portion of the device operates undisturbed.
Table 15.301. 0x0B4E Reserved Control
Reg Address
Bit Field
Type
Name
Description
0x0B4E
7:0
R/W
RESERVED
Internal use for initilization. See CBPro.
Table 15.302. 0x0B57 VCO_RESET_CALCODE
Reg Address
Bit Field
Type
Name
Description
0x0B57
7:0
R/W
VCO_RESET_CAL-
CODE
0x0B58
11:8
R/W
VCO_RESET_CAL-
CODE
Si5397/96 Reference Manual
Si5397A/B Register Map
silabs.com
| Building a more connected world.
Rev. 0.9 | 174