Table 15.28. 0x002D Loss of Signal Re-Qualification Value
Reg Address
Bit Field
Type
Setting Name
Description
0x002D
1:0
R/W
LOS0_VAL_TIME Clock Input 0
0: For 2 msec
1: For 100 msec
2: For 200 msec
3: For one second
0x002D
3:2
R/W
LOS1_VAL_TIME Clock Input 1, same as above
0x002D
5:4
R/W
LOS2_VAL_TIME Clock Input 2, same as above
0x002D
7:6
R/W
LOS3_VAL_TIME Clock Input 3,same as above
When an input clock is gone (and therefore has an active LOS alarm), if the clock returns, there is a period of time that the clock must
be within the acceptable range before the alarm is removed. This is the LOS_VAL_TIME.
Table 15.29. 0x002E-0x002F LOS0 Trigger Threshold
Reg Address
Bit Field
Type
Setting Name
Description
0x002E
7:0
R/W
LOS0_TRG_THR 16-bit Threshold Value
0x002F
15:8
R/W
LOS0_TRG_THR
ClockBuilder Pro calculates the correct LOS register threshold trigger value for Input 0, given a particular frequency plan.
Table 15.30. 0x0030-0x0031 LOS1 Trigger Threshold
Reg Address
Bit Field
Type
Setting Name
Description
0x0030
7:0
R/W
LOS1_TRG_THR 16-bit Threshold Value
0x0031
15:8
R/W
LOS1_TRG_THR
ClockBuilder Pro calculates the correct LOS register threshold trigger value for Input 1, given a particular frequency plan.
Table 15.31. 0x0032-0x0033 LOS2 Trigger Threshold
Reg Address
Bit Field
Type
Setting Name
Description
0x0032
7:0
R/W
LOS2_TRG_THR 16-bit Threshold Value
0x0033
15:8
R/W
LOS2_TRG_THR
ClockBuilder Pro calculates the correct LOS register threshold trigger value for Input 2, given a particular frequency plan.
Table 15.32. 0x0034-0x0035 LOS3 Trigger Threshold
Reg Address
Bit Field
Type
Setting Name
Description
0x0034
7:0
R/W
LOS3_TRG_THR 16-bit Threshold Value
0x0035
15:8
R/W
LOS3_TRG_THR
ClockBuilder Pro calculates the correct LOS register threshold trigger value for Input 3, given a particular frequency plan.