Bit 1 is the LOS status monitor for the XTAL or REFCLK at the XA/XB pins. Bit 3 is the XAXB problem status monitor and may indicate
the XAXB input signal has excessive jitter, ringing, or low amplitude. Bit 5 indicates a timeout error when using SMBUS with the I
2
C
serial port.
Table 15.10. 0x000D Loss-of Signal (LOS) Alarms
Reg Address
Bit Field
Type
Setting Name
Description
0x000D
3:0
R
LOS
1 if the clock input [3 2 1 0] is currently LOS.
0x000D
7:4
R
OOF
1 if the clock input [3 2 1 0] is currently OOF.
Note that each bit corresponds to the input. The LOS bits are not sticky.
• Input 0 (IN0) corresponds to LOS 0x000D [0], OOF 0x000D[4]
• Input 1 (IN1) corresponds to LOS 0x000D [1], OOF 0x000D[5]
• Input 2 (IN2) corresponds to LOS 0x000D [2], OOF 0x000D[6]
• Input 3 (IN3) corresponds to LOS 0x000D [3], OOF 0x000D[7]
Table 15.11. 0x000E Holdover and LOL Status
Reg Address
Bit Field
Type
Setting Name
Description
0x000E
3:0
R
LOL_PLL[D:A]
1 if the DSPLL is out of lock
0x000E
7:4
R
HOLD_PLL[D:A]
1 if the DSPLL is in holdover (or free run)
DSPLL_A corresponds to bit 0,4
DSPLL_B corresponds to bit 1,5
DSPLL_C corresponds to bit 2,6
DSPLL_D corresponds to bit 3,7
Table 15.12. 0x000F INCAL Status
Reg Address
Bit Field
Type
Setting Name
Description
0x000F
7:4
R
CAL_PLL[D:A]
1 if the DSPLL internal calibration is busy.
DSPLL_A corresponds to bit 4
DSPLL_B corresponds to bit 5
DSPLL_C corresponds to bit 6
DSPLL_D corresponds to bit 7
Table 15.13. 0x0011 Internal Error Flags
Reg Address
Bit Field
Type
Setting Name
Description
0x0011
0
R/W
SYSINCAL_FLG
Sticky version of SYSINCAL. Write a 0 to this bit to
clear.
0x0011
1
R/W
LOSXAXB_FLG
Sticky version of LOSXAXB. Write a 0 to this bit to
clear.
0x0011
2
R/W
LOSREF_FLG
Sticky version of LOSREF. Write a 0 to clear the flag.
0x0011
3
R/W
XAXB_ERR_FLG Sticky version of XAXB_ERR. Write a 0 to this bit to
clear.
Si5397/96 Reference Manual
Si5397A/B Register Map
silabs.com
| Building a more connected world.
Rev. 0.9 | 93