Appendix
A-2
7SA522 Manual
C53000-G1176-C119-2
1.1
Ordering Information and Accessories
Measured Current Inputs
I
Ph
= 1 A, I
E
= 1 A (min. = 0,05 A)
1
I
Ph
= 1 A, I
E
= highly sensitive (min. = 0,005 A)
2
I
Ph
= 5 A, I
E
= 5 A (min. = 0,25 A)
5
I
Ph
= 5 A, I
E
= highly sensitive (min. = 0,005 A)
6
Auxiliary Voltage (Power Supply, Pick-up Threshold of Binary Inputs)
DC 24 to 48 V, binary input threshold 17 V
2)
2
DC 60 to 125 V
1)
, binary input threshold 17 V
2)
4
DC 110 to 250 V
1)
, binary input threshold 73 V
2)
5
DC 220 to 250 V, AC 115 V, binary input threshold 154 V
2)
6
Housing, Number of Binary Inputs (BI) and Outputs (BO)
Flush mounting housing with screwed terminals
1
/
2
19“, 8 BI, 16 BO
A
Flush mounting housing with screwed terminals
1
/
1
19“, 16 BI, 24 BO
C
Flush mounting housing with screwed terminals
1
/
1
19“, 24 BI, 32 BO
D
Surface mounting housing with screwed terminals
1
/
2
19“, 8 BI, 16 BO
E
Surface mounting housing with screwed terminals
1
/
1
19“, 16 BI, 24 BO
G
Surface mounting housing with screwed terminals
1
/
1
19“, 24 BI, 32 BO
H
Flush mounting housing with plug-in terminals
1
/
2
19“, 8 BI, 16 BO
J
Flush mounting housing with plug-in terminals
1
/
1
19“, 16 BI, 24 BO
L
Flush mounting housing with plug-in terminals
1
/
1
19“, 24 BI, 32 BO
M
Region-Specific Default/Language Settings and Function Versions
Region GE, 50 Hz, IEC, German language (may be changed)
A
Region world, 50/60 Hz, IEC/ANSI, English language (may be changed)
B
Region US, 60 Hz, ANSI, US-English language (may be changed)
C
Region GE, 50 Hz, IEC, German language (may not be changed)
M
Region world, 50/60 Hz, IEC/ANSI, English language (may not be changed)
N
Region US, 60 Hz, ANSI, US-English language (may not be changed)
P
Regulations for Region-Specific Default and Function Settings:
Region US and EN: Stub bus DT visible as part of the overcurrent protection
Region DE: Stub bus DT not visible as part of the overcurrent protection; no ANSI; no miles
Region US: f = 60 HZ; only ANSI curves; fault locator preset to miles
System Interface (Rear Port)
no system interface
0
IEC protocol, electrical RS232
1
IEC protocol, electrical RS485
2
IEC protocol, optical 820 nm, ST-plug
3
Service Interface (DIGSI 4/Modem) (Rear Port)
no service interface
0
DIGSI 4, electrical RS232
1
DIGSI 4, electrical RS485
2
DIGSI 4, optical 820 nm, ST-plug
3
1) with plug-in jumper one of the 2 voltage ranges can be selected
2) for each binary input one of three pick-up threshold ranges can be selected with plug-in jumper
continued next page A-3
_
7SA522
7
8
13
15 16
14
_
9 10 11 12
Distance Protection
Содержание siprotec 7SA522
Страница 20: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 64: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 89: ...SIPROTEC 4 Devices 4 25 7SA522 Manual C53000 G1176 C119 2 Figure 4 20 CFC Logic example ...
Страница 408: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 456: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 516: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 620: ...Appendix B 48 ...