Hardware and Connections
2-17
7SA522 Manual
C53000-G1176-C119-2
such as closing or tripping circuit breakers. Next to the keypad, a labeling strip is
provided on which the user-specified key functions may be written.
7. 9-pin female D-subminiature connector
This serial interface is for the connection of a local PC running DIGSI
®
4.
8. LED key
This key has the dual purpose of resetting latched LEDs and the latched contacts
of output relays, as well as testing all of the LEDs.
9. Light emitting diodes (LEDs)
The function of these indicators can be programmed. There is a vast selection of
signals from which to choose. Some examples are device status, processing or
control information, and binary input or output status. Next to the LEDs on the front
panel, a labeling strip is provided on which the user-specified LED functions may
be written.
10. Operating condition indicators
The two LEDs “RUN” (green) and “ERROR” (red) indicate the operating condition
of the device.
11. Coverings for the screws that secure the front panel.
View of Front Panel
(Housing Size
1
/
1
)
The significance of the operating and display elements is the same as explained after
Figure 2-16.
Figure 2-17
Front view of a 7SA522, housing size
1
/
1
, for panel surface mounting, without optical connections
77 78 79 80 81 82 83 84 85
76
52 53 54 55 56 57 58 59 60
62 63 64 65 66
72
67 68 69 70 71
73 74 75
61
36 L+ L- 39 40 41
47
42 43 44 45 46
48 49 50
87 88 89 90 91
97
92 93 94 95 96
98 99 100
85
26 27 28 29 30 31 32 33 34 35
11 12 13 14 15 16
22
17 18 19 20 21
23 24 25
1
2
3
4
5
6
7
8
9
10
124
123
122
121
120
119
118
117
116
125
149
148
147
146
145
144
143
142
141
150
139
138
137
136
135
129
134
133
132
131
130
128
127
126
140
165
164
163
162
161
160
154
159
158
157
156
155
153
152
151
114
113
112
111
110
104
109
108
107
106
105
103
102
101
115
175
174
173
172
171
170
169
168
167
166
190
189
188
187
186
185
179
184
183
182
181
180
178
177
176
200
199
198
197
196
195
194
193
192
191
SIEMENS
SIPROTEC
1
2
6
3
+/-
0
5
4
7
8
9
7SA522
RUN
ERROR
MENU
ESC
LED
ENTER
F4
F1
F2
F3
Meldungen
Meßwerte
0$,10(18
$QQXQFLDWLRQ
0HDVXUHPHQW
Содержание siprotec 7SA522
Страница 20: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 64: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 89: ...SIPROTEC 4 Devices 4 25 7SA522 Manual C53000 G1176 C119 2 Figure 4 20 CFC Logic example ...
Страница 408: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 456: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 516: ...7SA522 Manual C53000 G1176 C119 2 ...
Страница 620: ...Appendix B 48 ...