Rev. 5.00, 12/03, page 477 of 1088
In serial reception, the SCI operates as described below.
[1] The SCI performs internal initialization in synchronization with serial clock input or output.
[2] The received data is stored in RSR in LSB-to-MSB order.
After reception, the SCI checks whether the RDRF flag is 0 and the receive data can be
transferred from RSR to RDR.
If this check is passed, the RDRF flag is set to 1, and the receive data is stored in RDR. If a
receive error is detected in the error check, the operation is as shown in table 12-11.
Neither transmit nor receive operations can be performed subsequently when a receive error
has been found in the error check.
[3] If the RIE bit in SCR is set to 1 when the RDRF flag changes to 1, a receive-data-full interrupt
(RXI) request is generated.
Also, if the RIE bit in SCR is set to 1 when the ORER flag changes to 1, a receive-error
interrupt (ERI) request is generated.
Figure 12-19 shows an example of SCI operation in reception.
Bit 7
Serial
data
Serial
clock
1 frame
RDRF
ORER
Bit 0
Bit 7
Bit 0
Bit 1
Bit 6
Bit 7
RXI interrupt request
generated
RDR data read and
RDRF flag cleared to 0
in RXI interrupt handling
routine
RXI interrupt request
generated
ERI interrupt request
generated by overrun
error
Figure 12-19 Example of SCI Receive Operation
•
Simultaneous serial data transmission and reception (synchronous mode)
Figure 12-20 shows a sample flowchart for simultaneous serial transmit and receive
operations.
The following procedure should be used for simultaneous serial data transmit and receive
operations.
Содержание H8S/2318 series
Страница 2: ......
Страница 6: ...Rev 5 00 12 03 page vi of xxx...
Страница 12: ...Rev 5 00 12 03 page xii of xxx...
Страница 30: ...Rev 5 00 12 03 page xxx of xxx...
Страница 54: ...Rev 5 00 12 03 page 24 of 1088...
Страница 98: ...Rev 5 00 12 03 page 68 of 1088...
Страница 128: ...Rev 5 00 12 03 page 98 of 1088...
Страница 138: ...Rev 5 00 12 03 page 108 of 1088...
Страница 168: ...Rev 5 00 12 03 page 138 of 1088...
Страница 212: ...Rev 5 00 12 03 page 182 of 1088...
Страница 324: ...Rev 5 00 12 03 page 294 of 1088...
Страница 436: ...Rev 5 00 12 03 page 406 of 1088...
Страница 546: ...Rev 5 00 12 03 page 516 of 1088...
Страница 580: ...Rev 5 00 12 03 page 550 of 1088...
Страница 822: ...Rev 5 00 12 03 page 792 of 1088...
Страница 876: ...Rev 5 00 12 03 page 846 of 1088...
Страница 901: ...Rev 5 00 12 03 page 871 of 1088 A 2 Instruction Codes Table A 2 shows the instruction codes...
Страница 1121: ...H8S 2319 Group H8S 2318 Group Hardware Manual REJ09B0089 0500O...