5.3.2.3 6th screen page: Optional parameters
The three red asterisks
***
at the top right indicate that this
evaluation has not yet been saved.
These measuring results of the optional parameters were
previously also referred to as a “traditional evaluation”.
Some of these parameters are also classified - depending
on setting - and are therefore also included in the individual
evaluation of the test results.
All other optional parameters have been configured prior to
the evaluation, so that these are displayed but are not to be
included in the evaluation.
The settings for the optional parameters can be individually
changed (refer also to chapter 5.6.1.3.3).
5.3.2.4 7th screen page: Error list
The error list from the measurement results:
A list contains all errors of the evaluation.
In this example, an element determination error was detected
and the value for the left quietzone was too small. This lead to
the evaluation of the overall measurement as class 0.
Additionally there was measured a too low modulation. To
reach the minimum quality, a modulation of 45% is necessary,
but only 40% was measured. This is indicated
under “03)”.
Three asterisks at the top right edge of the screen are always
shown on the evaluation pages if this evaluation has not yet
been saved locally in the device.
It is possible to scroll up and down through the individual
display screens of the evaluation views with the arrow keys.
The detailed description and interpretation of the individual measuring results and parameters can
be found in the separate training manual available from REA Elektronik GmbH.