3152A User Manual
Racal Instruments
©
2001
Using The Instrument 3-21
OFF places the instrument in Triggered mode. ON restores
continuous operation.
The query:
INITitiate:
CONTinuous?
queries the instrument operating mode parameter and returns
"0" (OFF) or "1" (ON).
Gated Mode
The Model 3152A can be set to operate in Gated mode only
after the INIT:CONT OFF command has been received. The
output remains at a certain DC level as long as the TRIG IN
signal from the front panel remains inactive. A TTL level signal is
used to stimulate the TRIG input. The gating signal can be
programmed to be either active high or active low. Each time
the proper level is present at the trigger input connector, the
Model 3152A generates output waveforms as long as the gate
signal is present. When the gate signal is de-asserted, the
output completes the last cycle and resumes position at a DC
level equal to the last point of the waveform.
Gated mode operates on standard waveforms, arbitrary
waveforms, and on sequences of waveforms. Observe the
limitations of the gating signal as listed in the specification
section of this manual. To place the Model 3152A in Gated
mode, use the following commands:
INIT:CONT
OFF
TRIGger: GATE {OFF | ON}
The default state for the Gated mode is OFF. Turning Gated
mode ON automatically turns Burst mode off.
The query:
TRIGger:GATE?
queries the gate state and returns "0" (OFF) or "1" (ON).
Содержание 3152A
Страница 5: ......
Страница 6: ...This page was left intentionally blank...
Страница 18: ...3152A User Manual xii This page was left intentionally blank...
Страница 25: ...3152A User Manual Racal Instruments 2001 Getting Started 1 7 Figure 1 2 3152A Front Panel...
Страница 156: ...3152A User Manual Product Support 6 4 Racal Instruments 2001 This page was left intentionally blank...