19. Didital Diagnostic Monitoring (DDM) Commands
203
The parameter type voltage allows the user to input the decimal in the CLI
command. The CLI does not restrict the number of input digits, the only
limitation of the inputted digits are the size of the command buffer and the
float-point precision. The user inputted digits will be converted to the floating-
point number and applied to the configuration database.
The default precision of a floating-point number is 6 digits.
For example, input "12.3456", will get a float value 12.3456, input
"12.3456789", will get a float value 12.3457.
Restrictions
Administrators and operators.
Example
To configure the port 21's voltage threshold
Zxxx0:admin# config ddm ports 21 voltage_threshold high_alarm 4.25 low_alarm 2.5
high_warning 3.5 low_warning 3
Command: config ddm ports 21 voltage_threshold high_alarm 4.25 low_alarm 2.5 high_w
arning 3.5 low_warning 3
Success.
Zxxx0:admin#