Install a Power Supply
Listen for the audible click when the power supply fully seats.
4.
Reconnect the power cord to the power supply.
5.
Verify that the amber LED on the replaced power supply and the service required
LEDs are not lit.
6.
Log in to the ILOM service processor as root.
Refer to the ILOM 3.0 documentation for instructions.
7.
At the ILOM prompt (
->
), type the
show /SYS/PS
n
command to verify the status of
the power supplies.
In this command,
PS
n
is the identifier for the power supply you plan to remove, either
PS0
or
PS1
.
Related Information
■
“Rear Panel Cable Connections” on page 17
■
“Power Supply LEDs” on page 23
■