Identify and Remove Faulty DIMMs
FIGURE 15
DIMM Socket Release and Alignment
Figure Legend
1
DIMM connector slot
2
DIMM connector key
3
DIMM ejector lever
8.
Replace each faulty DIMM with either another DIMM of the same rank size (quad
rank, dual rank, or single rank) or a DIMM filler panel.
For DIMM replacement instructions, see
.
Caution -
If you are not immediately inserting a replacement DIMM into the empty DIMM
socket, you should insert a DIMM filler panel in the socket to ensure adequate cooling and
reduce the possibility of a system shutdown.