Identify and Remove Faulty DIMMs
5.
Press the fault remind button on the motherboard to identify the location of the
faulty DIMMs.
6.
Note the location of faulty DIMMs.
Faulty DIMMs are identified when a corresponding amber service action required LED lights
next to the DIMM.
■
If the DIMM service action required LED is off: DIMM is operating properly.
■
If the DIMM service action required LED is on (amber): DIMM is faulty and should be
replaced.
138
Sun Netra X4270 Server • September 2015