![background image](http://html1.mh-extra.com/html/omron/f3sg-sr-series/f3sg-sr-series_user-manual_744123133.webp)
105
F3SG-SR
User’s Manual
Chapter
2
Warning Zone
System Operation and Functions
E
You can specify beams to configure for warning zone. (Fig. 4& 5)
Configuration cannot be executed for cases shown below.
• All beams are configured as a warning zone (Fig. 7).
• A warning zone is configured without including either the top end beam or bottom end beam. (Fig. 8)
When it is configured for the F3SG-SR in cascade connection to have the detection zone, it is possible
for the other F3SG-SR's to have the warning zone for the all beams. (Fig. 6)
For the application as shown in Fig. 6, make sure the primary sensor has the detection zone and the secondary sensor
has the warning zone.
Operation Example
Timing chart
Warning Zone
Detection Zone
Fig. 1
Fig. 2
Fig. 3
Safety output ON
Warning zone output OFF
Safety output ON
Warning zone output ON
Safety output OFF
Warning zone output OFF
Beam state
(Warning zone only)
Beam state
(Detection zone)
Unblocked
Blocked
AUX
(warning zone)
ON
OFF
Unblocked
Blocked
OSSD
ON
OFF
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...