141
F3SG-SR
User’s Manual
Chapter
3
Backup/Restoration
Setting with Intelligent Tap
E
3-6-4. Various Usage of Backup and Restoration
3-6-4-1. Plug and Work
If the F3SG-SR with the Intelligent Tap installed causes a fault, its settings can be reconfigured only by
replacing with a new F3SG-SR of the same model and turning its power ON.
3-6-4-2. Copy and Paste of Sensor Settings
You can configure the same settings to multiple F3SG-SR's by configuring one F3SG-SR, performing
the Backup to an Intelligent Tap, and restoring the settings to other F3SG-SR's.
3-6-4-3. Changing F3SG-SR Configuration to Connect to Intelligent Tap
If you want to change an F3SG-SR's configuration to connect to an Intelligent Tap or if you want to
connect the Intelligent Tap to another F3SG-SR, perform the Backup of the settings of the newly
connected F3SG-SR first.
3-6-4-4. Changing F3SG-SR's Settings with Intelligent Tap DIP Switch
To change the F3SG-SR's settings only by setting the DIP Switch on the Intelligent Tap without using
the SD Manager 3, follow the steps below.
1. If the light curtain is under operation while the Intelligent Tap is already connected
(1) Make sure the power is OFF.
(2) Make sure that the DIP Position 1 is set at ON (Lock), and set the Position 2 at ON (DIP Switch
Enabled).
(3) Configure other functions with the DIP Switch Positions 3 to 8.
(4) After restart, restoration is performed.
(5) When the Restoration is complete, the OUT indicator (green) blinks fast. Restart the F3SG-SR.
2. To reflect the DIP Switch settings to an F3SG-SR that has no Intelligent Tap connected
(1) Connect an Intelligent Tap to the F3SG-SR.
(2) Turn the power ON. Refer to “3-6-2. Performing Backup” for the procedure of the Backup.
(3) Perform the steps from (1) to (4) of the procedure No. 1 above.
(4) After the Restoration is complete, turn the power OFF and disconnect the Intelligent Tap.
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...