83
F3SG-SR
User’s Manual
Chapter
2
Muting
System Operation and Functions
E
Dynamic muting allowable beam
The dynamic muting allowable beam allows the muting zone measured by the Zone Measurement to
be expanded by the number of additional beam(s) specified as allowable beam.
Timing chart
2-13-6. Factory Default Setting
The muting mode is set to Standard Muting Mode and the Dynamic Muting to Disable.
2-13-7. Setting with Intelligent Tap
If the Pre-Reset function is enabled by the DIP Switch, the Muting function is disabled.
Otherwise the Muting function is always being enabled.
2-13-8. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
*Setting parameters of the following functions is saved according to the states where the Muting function is enabled and disabled
with the SD Manager 3, respectively. After changing the Muting function from Enable to Disable or from Disable to Enable, also
check the settings of these functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary Output
Refer to 2-26-6. Muting Statistics Information for more information.
Function
Initial value
Configurable value or numerical range
Muting function *
Enable
Enable/Disable
Muting mode
Standard muting mode
Standard Muting (Installation Example1) /
Standard Muting (Installation Example2) Exit-
only muting mode/Position detection muting
mode
Setting by
Manual
Manual/Teach-in
Statistics data recording
Enable
Enable/Disable
ON
OFF
Tdyn: Measurement time
Muting Input A
MUTING state
ON
OFF
ON
OFF
Enabled
Disabled
Zone Measurement
Beam state
Unblocked
Blocked
Partial Zone
Tdyn (3 s)
All Zone
Muting Input B
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...