64
Chapter
2
Muting
F3SG-SR
User’s Manual
System Operation and Functions
End conditions
If either of the following conditions is satisfied, the MUTING state is released.
• The muting input A or B turns OFF for the maximum allowable muting signal interruption of T3 (at
least 0.1 s: configurable) or longer.
• The duration of the MUTING state exceeds the muting time limit of T2 (at least 60 s: configurable).
The MUTING state is also released when the F3SG-SR enters the LOCKOUT state.
Timing chart
Factory default setting
Variable
Variable name
Value
Description
T
1min
Muting input time limit value
(minimum)
0.1 s
Minimum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is smaller
than this value, a muting sequence error occurs.
T
1max
Muting input time limit value
(maximum)
4 s
Maximum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is larger
than this value, a muting sequence error occurs.
T
2
Muting time limit
60 s
The duration time of the Muting function. The MUTING state is
cancelled if it continues for longer than this time limit.
T
3
Maximum allowable muting
signal interruption
0.1 s
Maximum duration of a signal interruption allowed in muting
inputs A and B.
T1min: Muting input time limit value (minimum)
T1max: Muting input time limit value (maximum)
T2: Muting time limit
T3: Maximum allowable muting signal interruption
* 102 ms max. when the
Intelligent Tap is connected
to the F3SG-SR.
T2 max.
Green blinking
Orange blinking
Orange
blinking
T3 max.
T3 max.
T1min to T1max
80 ms max. *
Muting input A
ON
OFF
Muting input B
MUTING state
Enabled
Disabled
OSSD
ON
OFF
ABI indicator
ON
OFF
Unblocked
Blocked
ON
OFF
Beam state
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...