![background image](http://html1.mh-extra.com/html/omron/f3sg-sr-series/f3sg-sr-series_user-manual_744123040.webp)
12
Chapter
1
Ratings and Specifications
F3SG-SR
User’s Manual
Overview and Specifications
1-5. Ratings and Specifications
Extension of the cable must be within a specified length. If it isn't, safety functions may not work
properly, resulting in danger.
1-5-1. F3SG-SR Series
The
in the model names indicate the protective heights in millimeters.
Model
F3SG-
SRA
-14
F3SG-
SRB
-14
F3SG-
SRA
-25
F3SG-
SRB
-25
F3SG-
SRA
-45
F3SG-
SRB
-45
F3SG-
SRA
-85
F3SG-
SRB
-85
Performance
Object resolution
(Detection capability)
Opaque objects
14-mm dia.
25-mm dia.
45-mm dia.
85-mm dia.
Beam gap
10 mm
20 mm
40 mm
80 mm
Number of beams
15 to 199
8 to 124
6 to 38
4 to 12
Lens size
4.4
3.4 mm (W
H) 6.7
4.5 mm (W
H)
Protective height
160 to 2,000 mm
160 to 2,480 mm
240 to 1,520 mm
280 to 920 mm
Operating
range
Long
0.3 to 10.0 m *
0.3 to 20.0 m
Short
0.3 to 3.0 m *
0.3 to 7.0 m
* When operating at an ambient temperature of -10 to -30°C, use the F3SG-SR with the operating range
of 0.3 to 5.0 m in Long Mode and 0.3 to 1.5 m in Short Mode.
Response time
*1
Normal
mode
ON to
OFF
Optical
synchronization:
8 to 18 ms
Wired
synchronization:
10 to 21 ms
Optical
synchronization:
8 to 13 ms
Wired
synchronization:
10 to 17 ms
Optical synchronization: 8 ms
Wired synchronization: 10 ms
OFF
to ON
Optical
synchronization:
40 to 90 ms
Wired
synchronization:
50 to 105 ms
Optical
synchronization:
40 to 65 ms
Wired
synchronization:
50 to 85 ms
Optical synchronization: 40 ms
Wired synchronization: 50 ms
×2 Slow
mode *2
ON to
OFF
Optical
synchronization:
16 to 36 ms
Wired
synchronization:
20 to 42 ms
Optical
synchronization:
16 to 26 ms
Wired
synchronization:
20 to 34 ms
Optical synchronization: 16 ms
Wired synchronization: 20 ms
OFF
to ON
Optical
synchronization:
80 to 180 ms
Wired
synchronization:
100 to 210 ms
Optical
synchronization:
80 to 130 ms
Wired
synchronization:
100 to 170 ms
Optical synchronization: 80 ms
Wired synchronization: 100 ms
×4 Slow
mode *2
ON to
OFF
Optical
synchronization:
32 to 72 ms
Wired
synchronization:
40 to 84 ms
Optical
synchronization:
32 to 52 ms
Wired
synchronization:
40 to 68 ms
Optical synchronization: 32 ms
Wired synchronization: 40 ms
OFF
to ON
Optical
synchronization:
160 to 360 ms
Wired
synchronization:
200 to 420 ms
Optical
synchronization:
160 to 260 ms
Wired
synchronization:
200 to 340 ms
Optical synchronization: 160 ms
Wired synchronization: 200 ms
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...