218
Chapter
4
Changing Settings with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
4-3-5-2. Stable Light Threshold Adjustment
First, carry out 4-3-1. Preparing to Change Settings.
Next, on the Top page, click the icon below.
The setting screen below is displayed.
When the stable light threshold value is changed, the following threshold values of the output information are also
changed.
· Auxiliary Output: Stable-state information and Light level diagnosis information (upper limit)
· Area Beam Indicator: Stable-state information and Light level diagnosis information (upper limit)
· IO-Link Process Data: Light level diagnosis information (upper limit)
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor]
button.
No.
Function name
Description
Initial value
Configurable value or
numerical range
1
Stable light threshold
Set stable light threshold. Set the parameter by moving
the pointer of the bar.
170%
100 to 300%
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...