33
F3SG-SR
User’s Manual
Chapter
2
Operating States
System Operation and Functions
E
2-2. Operating States
The following operating states exist for the F3SG-SR and Intelligent Tap.
2-2-1. Operating States of F3SG-SR and Intelligent Tap
MACHINE RUN State
The two safety outputs are in the ON state and the green OSSD indicator on the receiver is illuminated.
The protected machine is allowed to operate. Pressing and releasing the reset switch has no effect.
MACHINE STOP State
The two safety outputs are in the OFF state and the red OSSD indicator on the receiver is illuminated.
The protected machine is not allowed to operate. If connecting the sensor with the Intelligent Tap to
use it, the IN and OUT indicators of the Intelligent Tap is lit up in yellow and green, respectively.
INTERLOCK State
The two safety outputs are in the OFF state and the yellow SEQ indicator on the receiver is illuminated.
The INTERLOCK state does not allow the protected machine to operate until the detection zone is
clear of obstructions and the reset switch is pressed and released.
Refer to 2-8. Interlock for more information.
LOCKOUT State
The two safety output signals is in the OFF state, and each indicator is illuminated or blinks as shown
in the table below. In addition, the indicator which has detected an error is illuminated or blinks to
display the error. The LOCKOUT state does not allow the protected machine to operate. The primary
difference between LOCKOUT and INTERLOCK states is that the F3SG-SR system will remain in the
LOCKOUT state until the cause of the error is corrected, regardless of power cycling or an external
reset switch press and release.
Refer to 8-1-2. LOCKOUT State for more information.
TEACH-IN Mode
The two safety outputs are in the OFF state and the green CFG indicator on the receiver is blinking.
Refer to 8-1-2. LOCKOUT State for more information of the error indication.
Condition
Device
Indicator
Name
Color
Illuminated
Blinking
The F3SG-SR is
in the LOCKOUT
state.
Emitter
or
Lockout
Red
-
LOCKOUT state
Receiver
or
Lockout
Red
-
LOCKOUT state
or
Maintenance
Red
LOCKOUT state due to
a recoverable error
(When in cascade
connection, the
indicator of only the
sensor segment having
the error is illuminated)
LOCKOUT state due to
a replacement-
recommended error
(When in cascade
connection, the
indicator of only the
sensor segment having
the error blinks)
Intelligent
Tap
IN
Sensor
status
Yellow
-
The F3SG-SR is in the
LOCKOUT state.
The Intelligent
Tap is in the
LOCKOUT state
Intelligent
Tap
ERR
Lockout
Red
The Intelligent Tap is in
the LOCKOUT state
-
Receiver
or
Maintenance
Orange
-
Intelligent Tap is in the
LOCKOUT state
E
ERR
E
ERR
M
MAINT
M
MAINT
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...