346
Chapter
8
Troubleshooting
F3SG-SR
User’s Manual
Appendix
Configuration error
X
X
34
An error may have occurred to the internal information of
the model name of the F3SG-SR due to effect of noise.
If other devices using the same power supply generate
noise, do not share the same power supply with other
devices, and use a separate power supply exclusively for
the safety components.
The inductive noise tends to be induced especially if the
power supply line of the machine guarded and the power
supply line of the Intelligent Tap are arranged in parallel.
Arrange the exclusive power supply near the Intelligent
Tap or lay the power supply line of the Intelligent Tap away
from the power supply line of the machine guarded.
If the power supply for the Intelligent Tap is located near
the power supply of the machine guarded and it shares the
same grounding wire, it is subject to the influence of
common mode noise.
Separate the grounding point or use it as the exclusive
ground.
5-4-4. Functional Earth Connection
An error may have occurred in the internal circuit.
Replace the F3SG-SR.
Parameter error
X
X
F1
The settings do not match between the Intelligent Tap and
F3SG-SR. Perform the Backup.
40
The settings of the F3SG-SR may be faulty. Check if the
settings are correct.
Cap error
X
X
4F
A cap may be detached. Attach the cap properly.
Other sensor error
X
X
38
Other sensor being cascaded caused an error. Check the
indicator of the sensor.
DIP Switch setting error
X
X
E7, E8
A DIP Switch on the Intelligent Tap setting may have been
changed during operation.
Check if a DIP Switch setting was changed or not.
Communication error
-
X
30, 32
The communication lines or other lines may be short-
circuited or broken.
Check if the cascading or extension cables. If the
cascading cable or extension cables is broken, replace it.
31
An error may have occurred to the communication due to
effect of noise.
If other devices using the same power supply generate
noise, do not share the same power supply with other
devices, and use a separate power supply exclusively for
the safety components.
The inductive noise tends to be induced especially if the
power supply line of the machine guarded and the power
supply line of the Intelligent Tap are arranged in parallel.
Arrange the exclusive power supply near the Intelligent
Tap or lay the power supply line of the Intelligent Tap away
from the power supply line of the machine guarded.
If the power supply for the Intelligent Tap is located near
the power supply of the machine guarded and it shares the
same grounding wire, it is subject to the influence of
common mode noise.
Separate the grounding point or use it as the exclusive
ground.
5-4-4. Functional Earth Connection
An error may have occurred in the internal circuit.
Replace the F3SG-SR.
Description
Checking by
Error code
(HEX)*
Cause and measures
Indicator
SD Manager 3/
SD Manager 3
Mobile APP
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...