51
F3SG-SR
User’s Manual
Chapter
2
PSDI
System Operation and Functions
E
2-10. PSDI
To use the F3SG-SR in PSDI mode (initiation of cyclic operation by a presence sensing device),
you must configure an appropriate circuit between the F3SG-SR and the machine. For details
about PSDI, refer to OSHA 1910.217, IEC 61496-1, and other relevant standards and
regulations.
2-10-1. Overview
PSDI (Presence Sensing Device Initiation) is the function that F3SG-SR judges the unblocked/blocked
state of the detection zone and operates the machine cyclically (repeatedly). Operations of two-hand
push button switches are made unnecessary majorly on press machines, so operator’s burden can be
reduced and machine availability can be improved.
The following two types of PSDI can be realized without using controllers.
• Single break
The press machine of manual loading and automatic unloading is restarted in this mode by blocking of
the light curtain and unblocking after that.
• Double break
The press machine of manual loading and manual unloading is restarted in this mode after blocking
and unblocking of the light curtain is repeated twice.
F3SG-SRA
F3SG-SRB
wo
rk
peace
Workpiece setting
The press machine is
restarted automatically by
confirmation of unblocking.
The press machine stops, ejects
the workpiece automatically, and
waits for next workpiece setting.
Workpiece setting
Execution of
cyclic operation
wo
rk
peace
Workpiece setting
The press machine is
restarted automatically by
confirmation of unblocking.
The press machine stops, the workpiece
is ejected manually, and the machine
waits for next workpiece setting.
Workpiece setting
Execution of
cyclic operation
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...