56
Chapter
2
External Device Monitoring (EDM)
F3SG-SR
User’s Manual
System Operation and Functions
2-11-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
* Setting parameters of this function is saved according to the states where the Muting function is enabled and disabled,
respectively. After changing the Muting function from Enable to Disable or from Disable to Enable with the SD Manager 3, also
check the settings of this function again.
Refer to
Considerations for enabling and disabling Muting function with SD Manager 3
Functions for more information.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
After you make any change to the setting, verify that the F3SG-SR goes to the LOCKOUT state when the F3SG-SR is
wired in such a way that the specified voltage is applied directly to the RESET line of the receiver without the NC contact
of an external device.
Function
Initial value
Configurable value or numerical range
Muting function enabled*
Muting function disabled*
EDM
Disable
Disable
Enable/Disable
Allowable delay time
0.3 s
0.3 s
0.1 to 4 s in 0.1-s increments
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...