Dimensions
Wiring and Installation
E
5-2. Dimensions
5-2-1. F3SG-SR Series
5-2-1-1. Mounted with Side-Mount Brackets (Intermediate Brackets) (F39-LSGF)
Backside Mounting
5-3-4-1. Mounting with Side-Mount Brackets (Intermediate Brackets) (F39-LSGF)
- Use the brackets of specified quantities and locations according to the dimensions. The other brackets than described
above may not meet the specified ratings and performance.
- When you use the sensor in a situation where the sensor is under a load, increase the number of the brackets used.
- Beam alignment cannot be performed with Side-Mount Brackets.
250 max.
250 max.
F
10
P
D
250 max.
F
250 max.
C
5.7
5.7
<Screw: M5 or M6>
50
38
5.7
34.4
6.3 dia.
C(Protective height)
32
46.7
Side-Mont
Bracket
(F39-LSGF)
Side-Mont
Bracket
(F39-LSGF)
2-M5
or M6
2-M5
or M6
[ Unit : mm ]
* The number of brackets required to mount either one of emitter and receiver. The side-mount brackets (intermediate brackets) are included with
the light curtain.
Dimension C
4-digit number of the type name (Protective height:
)
Dimension D
F3SG-
SR
-14
C-20
F3SG-
SR
-25
F3SG-
SR
-45
C-40
F3SG-
SR
-85
Dimension P
F3SG-
SR
-14
10
F3SG-
SR
-25
20
F3SG-
SR
-45
40
F3SG-
SR
-85
80
Protective height
(Dimension C)
Number of Side-Mount
Bracket *
Dimension F
0160 to 1440
2
1000 mm max.
1520 to 2480
3
1000 mm max.
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...