116
Chapter
2
Designated Beam Output
F3SG-SR
User’s Manual
System Operation and Functions
2-23. Designated Beam Output
2-23-1. Overview
This function allows information on unblocked/blocked states of a given beam to be output.
Example:
• To turn Area Beam Indicator (ABI) ON when a specified beam of the F3SG-SR is blocked
• To output, from the auxiliary output, a signal of information on a specified beam being unblocked
If one or more specified beams are blocked or unblocked, the information on the beam state can be
provided as an auxiliary output or Area Beam Indicator (ABI).
Operation Example
Designated beam state: Dark-ON
2-23-2. Factory Default Setting
Designated Beam Output is disabled.
2-23-3. Setting with Intelligent Tap
The user cannot make any changes to the settings of this function by the DIP Switch on the Intelligent
Tap.
F3SG-SRA
F3SG-SRB
Safety output ON
Safety output OFF
Safety output OFF
Designated beam output OFF
Designated beam output ON
Designated beam output OFF
Figure 1
Figure 2
Figure 3
Designated
beam
Designated
beam
Beam state
Beam state
(Designated beam)
Unblocked
Blocked
(Other than designated beam)
Designated beam output
ON
OFF
Unblocked
Blocked
OSSD
ON
OFF
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...