2-16-2. Factory Default Setting
The Floating Blanking is disabled.
2-16-3. Setting with Intelligent Tap
Floating blanking can be configured using Positions 6 and 7 of the DIP Switch of the Intelligent Tap.
The Floating Blanking Monitoring function is configured as Lockout.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
2-16-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
Setting is required for each sensor segment in case of a cascade connection.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Setting the Floating Blanking Monitoring function to Disable Monitoring may create an undetectable area where a person
can block the F3SG-SR without being detected, and it is not compliant with IEC 61496-2. Conduct risk assessment
analysis thoroughly before enabling this setting.
Refer to Chapter 4 Setting with SD Manager 3 for more information on changing functions by SD Manager 3.
Function
Initial value
Configurable value or numerical range
Floating Blanking
Disable
Enable/Disable
Floating Blanking Monitoring
Lockout
Disable monitoring/Lockout/Cancel blanking zone
Temporarily Disable Monitoring
Function
Disable
Enable/Disable
Monitoring temporarily disabled
time limit
10 s
1 to 200 s (1-s increments), or infinite
Number of floating beams
1
1 to 15 beams (1-beam increments)
Number of allowable beams
0
0 to 5 beams (1-beam increments)
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...