15
F3SG-SR
User’s Manual
Chapter
1
Ratings and Specifications
Overview and Specifications
E
Environmental Ambient
temperature
Operating
-30 to 55 °C (non-icing)
Storage
-30 to 70 °C
Ambient
humidity
Operating
35% to 85% (non-condensing)
Storage
35% to 95%
Ambient illuminance
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of protection
(IEC 60529)
IEC 60529: IP65 and IP67, JIS C 0920 Annex 1: IP67G
Vibration resistance
(IEC 61496-1)
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock resistance
(IEC 61496-1)
100 m/s
2
, 1000 shocks for all 3 axes
Pollution degree
(IEC 60664-1)
3
Connections Root cable
Type of
connection
To sensors: dedicated connector, To external: M12 connector type (5-pin emitter and 8-
pin receiver) or open-ended type
IP67 and IP67G (JIS C 0920 Annex 1) * rated when mated.
* The F3SG-SR meets the degree of protection when the root cable is correctly
connected with the F3SG-SR. The degree of protection is not satisfied with the part
where cable wires are uncovered.
Number of
wires
Emitter: 5, Receiver: 8
Cable length
See 5-4-3-1. Root-Straight Cable and 5-4-3-2. Root-Plug Cable for Extended
for more information.
Cable
diameter
6 mm
Minimum
bending radius
R5 mm
Cascading
cable
Type of
connection
To sensors: dedicated connector, To cascading sensors: M12 connector type (5-pin
emitter and 8-pin receiver) or dedicated connector
IP67 and IP67G (JIS C 0920 Annex 1) * rated when mated.
* The F3SG-SR meets the degree of protection when the cascading cable is correctly
connected with the F3SG-SR and the root cable.
Number of
wires
Emitter: 5, Receiver: 8
Cable length
See 5-4-3-5. Cascading Cable for Extended for more information.
Cable
diameter
6 mm
Minimum
bending radius
R5 mm
Extension
cable
- Extended
Socket-
Straight
Cable
- Extended
Plug-Socket
Cable
Type of
connection
M12 connector type (5-pin emitter and 8-pin receiver), IP67* rated when mated
The extension cable meets the degree of protection when the root cable is correctly
connected with the extension cable.The degree of protection is not satisfied with the
part where cable wires are uncovered.
Number of
wires
Emitter: 5, Receiver: 8
Cable length
See 5-4-3-3. Extended Socket-Straight Cable and 5-4-3-4. Extended Plug-
Socket Cable for more information.
Cable
diameter
6.6 mm
Minimum
bending radius
R36 mm
Model
F3SG-
SRA
-14
F3SG-
SRB
-14
F3SG-
SRA
-25
F3SG-
SRB
-25
F3SG-
SRA
-45
F3SG-
SRB
-45
F3SG-
SRA
-85
F3SG-
SRB
-85
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...