189
F3SG-SR
User’s Manual
Chapter
4
Basic Operation of SD Manager 3
Setting with SD Manager 3
E
4-2-9. Safety Distance Calculation
Click the [Safety Distance Calculation] button
from the [Main] menu on the tool bar or directly
from the tool menu.
For safety distance, refer to 5-1-2. Safety Distance. The calculation is based on values entered in the screen.
To calculate on the actually connected F3SG-SR, execute [Retrieve information saved in F3SG] to update the numerical
values.
No.
Function
Description
1
Types of safety distance
Select a type of safety distance to be calculated.
2
Retrieve information from sensor
Update the data in [Input Information] to reflect the information in [Retrieve
information stored in sensor].
3
Calculate
Calculates safety distance according to the specified condition.
4
OK
Closes the [Safety Distance Calculation] window.