53
F3SG-SR
User’s Manual
Chapter
2
PSDI
System Operation and Functions
E
2-10-2. Factory Default Setting
The PSDI function is set disabled.
2-10-3. Setting Change using Intelligent Tap
It is unable to change the setting of this function using the DIP Switch of the Intelligent Tap.
2-10-4. Setting Change using SD Manager 3
The following setting can be made using SD Manager 3.
* Set the minimum pressing time of the reset switch and pre-reset switch. The same minimum pressing time is applied to both
the switches.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Function
Initial value
Configurable value or numerical range
PSDI function
Disabled
Disable/Single break/Double break
Minimum pressing time of reset switch *
100 ms
100 to 500 ms in 100-ms increments
T1
min.
T1
min.
T2
min.
Dummy
break
Dummy
break *
1
Dummy
break *
1
Unintended
break
Feeding
parts
Removing
parts
Feeding
parts
T3
min.
T4
min.
T2
min.
T3
min.
T6
Machine stops
T4
min.
T2
min.
T3
min.
T4
min.
T5
以上
T5
min.
Double Break
Reset switch (S1)
Press position
switch (S3)
OSSD
T1: Minimum pressing time of reset switch, configurable by 100 ms in a range of 100-500 ms
T2: Minimum break time (300 ms)
T3: Minimum unblocked time during the time from removing to feeding parts. T3 = T1
T4: Minimum break time (300 ms)
T5: Minimum pressing time of press position switch. T5 = T1
T6: Wait time until double break is complete (30 s or less)
*1. When the machine is stopped by unintended block in the middle of pressing of parts, operation of the reset switch (S1)
and then double dummy break are needed for reinitiation of the machine cycle.
*2. When Auxiliary Output is set to PSDI Information by the SD Manager 3.
AUX*
2
SEQ indicator
(yellow)
Beam state
Unblocked
Blocked
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON 1 time
Solid-ON
Machine restarts
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...