278
Chapter
5
Mounting
F3SG-SR
User’s Manual
Wiring and Installation
2.
Fully loosen the Mounting Screws (hexagon socket head cap screw (M4×22)). Fit the Brackets (1) and
(2) to the backside of the sensor housing so that the groove of the backside of the housing receives the
hooks of the Brackets (1) and (2). (Fig. 2)
3.
Securely tighten the Mounting Screws to fix the Adjustable Side-Mount Bracket to the sensor housing.
The recommended torque to tighten the Mounting Screws is 3.0 N•m. Then loosen the Alignment
Screws (hexagon socket head cap screws (M4×22)). (Fig. 3)
Tightening screws with a torque that considerably exceeds the recommended torque may cause failure.
Mounting Screw
(hexagon socket head
cap screw (M4×22))
Fit the hooks of Adjustable
Side-Mount Brackets to the
groove of the backside of
the housing
Loosen
Bracket (1)
Bracket (2)
Hook
Fig. 2
Alignment Screw
(hexagon socket head
cap screw (M4×22))
Mounting Screw
Mounting Screw
Alignment Screw
(hexagon socket head
cap screw (M4×22))
Mounting Screw
Alignment Screw
2. Loosen
1. Securely
tighten
2. Loosen
1. Securely
tighten
Fig. 3
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...