68
Chapter
2
Muting
F3SG-SR
User’s Manual
System Operation and Functions
This distance must prevent the MUTING state from being enabled by a person passing through the
muting sensors.
Also, install the F3SG-SR and muting sensors so that each workpiece passes through all muting
sensors before the next workpiece arrives at the first muting sensor.
Wiring diagram (PNP)
Timing chart
B1
A1
+24 VDC
0 V
Power
supply
MUTE B: Pink
MUTE A: Gray
MUTE B: Pink
MUTE A: Gray
Reflector
Reflector
A1
B1
F3SG-SR
Using a photoelectric sensor as a muting sensor
Note. Two-wire type muting sensor cannot be used.
Using an NO contact type switch as a muting sensor
A1, B1: Retro-reflective
photoelectric sensor
- PNP Output
- Dark-ON
A1, B1: NO contact type switch
T2 max.
T3 max.
T3 max.
T1min to T1max
80 ms max. *
Green blinking
Orange blinking
Orange
blinking
Muting sensor A1
ON
OFF
Muting sensor B1
Unblocked
Blocked
OSSD
ON
OFF
ON
OFF
MUTING state
Enabled
Disabled
Beam state
ABI indicator
ON
OFF
T1min: Muting input time limit value (minimum)
T1max: Muting input time limit value (maximum)
T2: Muting time limit
T3: Maximum allowable muting signal interruption
* 102 ms max. when the
Intelligent Tap is connected
to the F3SG-SR.
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...