![background image](http://html1.mh-extra.com/html/omron/f3sg-sr-series/f3sg-sr-series_user-manual_744123121.webp)
93
F3SG-SR
User’s Manual
Chapter
2
Fixed Blanking
System Operation and Functions
E
• When beams are blocked within the range from [1 beam next to bottom beam] to [1 beam next to top beam]
When beams are blocked within the range from [1 beam next to bottom beam] to [1 beam next to top beam],
allowable beams are configured as follows.
The table below lists the number of allowable beams when a fixed blanking zone and allowable beams
are configured with the SD Manager 3.
Number of allowable beams available for fixed blanking beams
Refer to 3-7-1. Setting Fixed Blanking by Teach-in for more information on Teach-in with the DIP Switch.
For detection capability on the border between the blanking zone and normal detection zone when
allowable beam is configured, see next table.
Detection capability on the border between the blanking zone and normal detection zone when
allowable beam is specified.
[mm]
LED indicator status
When the Fixed Blanking is being enabled, the CFG indicator turns on.
Number of blocked
beams
Number of allowable beams
Zone with allowable beam configured
Figure
No.
Upper
Lower
1 or 2
1
1
Outside the blocked zone
Fig. 5
3 or more
2
2
1 beam each for outside and inside the blocked zone
Fig. 6
Number of fixed blanking beams
Maximum number of allowable beams
1
Setting not possible
2
1
3
2
4
3
n
n-1
Allowable beam
on one end
F3SG-
SR
-14 F3SG-
SR
-25 F3SG-
SR
-45 F3SG-
SR
-85
Disable
14 (same as nominal)
25 (same as nominal)
45 (same as nominal)
85 (same as nominal)
1 beam
24
45
85
165
2 beams
34
85
125
245
n beams
14+(10×n)
25+(20×n)
45+(40×n)
85+(80×n)
1 or 2 beams
are blocked
Fig. 5
Allowable beam
(1 beam outside
the blocked zone)
Fixed blanking zone
Blocked zone
Upper
Lower
3 or more beams
are blocked
Fig. 6
Fixed blanking zone
Blocked zone
Bottom beam
1 beam
next to
top
beam
Blocked
within
this range
Top beam
1 beam
next to
bottom
beam
Allowable beam
(1 beam outside
the blocked zone)
Allowable beams
(1 beam each for
outside and inside
the blocked zone)
Allowable beams
(1 beam each for
outside and inside
the blocked zone)
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...