The safety distance is the distance that must be set between the F3SG-SR and a machine's
hazardous part to stop the hazardous part before a person or object reaches it. The safety distance
varies according to the standards of each country and the individual specifications of each machine.
Always refer to the relevant standards.
Make sure to install the F3SG-SR at the safety distance from the hazardous part of the
machine. Otherwise, the machine may not stop before a person reaches the hazardous
part, resulting in serious injury.
The response time of a machine is the time period from when the machine receives a stop signal to when the machine's
hazardous part stops. Measure the response time on the actual system. Also, periodically check that the response time
of the machine has not changed.
5-1-2-1. Safety Distance Formulas according to ISO 13855/EN ISO 13855
Detection Zone Orthogonal to Direction of Approach
S = K x T + C . . . Formula (1)
• S: Safety distance
• K: Approach speed to the detection zone
• T: Total response time of the machine and the F3SG-SR
• C: Additional distance calculated by the detection capability
(or object resolution) of the F3SG-SR
Calculation Example for Systems with a Detection
Capability of 40 mm or Less
Use K = 2,000 mm/s and C = 8 x (d - 14 mm) in formula (1)
for the calculation.
S = 2,000 mm/s x (Tm + Ts) + 8 x (d - 14 mm)
• S = Safety distance (mm)
• Tm = Machine's response time (s)
• Ts = Response time of the F3SG-SR from ON to OFF (s)
• d = Detection capability (or object resolution) of the F3SG-SR (mm)
[Calculation example]
When Tm = 0.05 s, Ts = 0.008 s, and d = 14 mm:
S=2,000 mm/s x (0.05 s + 0.008 s) + 8 x (14 mm - 14 mm)
= 116 mm . . . Formula (2)
If the result
<
100 mm, use S = 100 mm.
If the result exceeds 500 mm, use the following expression where K = 1,600 mm/s.
S=1,600 mm/s x (Tm + Ts) + 8 x (d - 14 mm) . . . Formula (3)
If the result of this formula (3)
<
500 mm, use S = 500 mm.
Hazard
Safety distance (S)
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...