The JA-150A II Internal wireless siren 

The JA-150A II Internal wireless siren 

1 / 2 

MLP20100 

The JA-150A  II  siren  is a component of the 

JABLOTRON 100+ 

system. It is used for alarm indication inside a building  with  

the possibility to distinguish between types of alarm with different types 

of indications.  It can also be used for other acoustic indications (PG 

outputs, entry/exit delays, a doorbell). Pressing a  button  on the siren 

can silence the alarm  indication in progress  (which can also confirm 

somebody’s presence on the premises or trigger a panic alarm (optional 

function). The siren is equipped with a backup battery for cases when 

AC dropouts occur. The siren takes one position in the system and 

should be installed by a trained technician with a valid certificate issued 

by an authorized distributor. 

 

Installation 

The siren can be installed directly on a plaster wall or into a special 

enclosure. The siren contains front and rear tamper contacts. 

 

 

Figure 1: Disassembly of the siren before installation

 

1.  Remove the body (buttons)  of the siren from the plastic  frame  

by pressing on a side of the body (

1.

) using a screwdriver as shown  

in figure 1.  

2.  Remove the middle  part of the frame (3.) by pushing the  4  tabs 

indicated by arrows (

2.

)  

3.  Push  the power cable through  a  designated rectangular  recess  

in the plastic base. 

4.  Attach the plastic base to the selected place using screws.  Place 

the BAT-3V2-CR2 battery underneath the top side of the plastic base 

as shown in figure 1. 

5.  Connect the power supply cable to the terminals following figure 2 (3), 

connect the battery (2) to the PCB placed on the plastic base (2). 

6.  Assemble  the  plastic frame with the plastic base which will fix  

the battery in position. 

7.  Connect  the  body (buttons)  to a connector (4) and assemble 

it with the plastic frame.  Attention, the tamper sensor (6) must  

be positioned above the magnet (5) on the plastic base.  

8.  Proceed  by  following  the control panel installation manual.  Basic 

instructions: 
a.  When the power supply is connected, the yellow LED (1) starts 

flashing to indicate the siren has not yet been enrolled into the system. 

b.  Open the 

F-Link

  software, select an unused position  

in the 

Devices

  tab  and click on the 

Enroll

  button  to launch  

the enrollment mode.  

c. 

Press  one  of the  siren buttons  (at the top or at the bottom) – 

the siren is now enrolled and the yellow LED indicator switches off.

 

 

Figure 2: 1 – battery; 2 – battery connector; 3 – 230V AC mains power 

terminal; 4 – Siren to PCB connector; 5 – tamper magnet; 6 – tamper sensor; 

7 – internal buttons; 8 – production number; 9 – LED indicator;  

10 – piezo-electric siren; 11 – tabs 

Notes: 

  The enrollment of  the siren to the control panel is also possible  

by entering the production code via the F-Link software. 

The production code is on a sticker with a bar code which is glued 

onto the rear side of the siren or onto the PCB (8). All digits  

of the production number  are required (example: 1400-00-0000-

0001). 

  If you want to remove the siren from the system, erase it from its 

position in the F-Link software. 

Setting properties 

Open the F-Link software, go to the 

Devices 

tab. Click on the 

Internal 

settings

  option at the siren’s position to open a dialog window where 

you can set the following options: (* indicates default settings). 

The Setting tab: 
Acoustic indication of an intrusion alarm from sections: 

The selection  

of sections which should indicate an intrusion alarm via the siren. The default 

setting is the indication of an intrusion from all sections. 

Reaction

Determines  whether the siren should indicate

 

IW*

  (internal 

warning) or 

EW

 (external warning) signals. Alarm indication with this siren 

can also be completely disabled (other functions remain active). 

Siren sound: 

Intermittent

*, 

Continuous

 

Maximum siren time: 

1, 2, 3*, 4, 5

 

minutes 

and

 OFF

 – if the OFF option  

is selected then the acoustic indication corresponds with the 

Alarm length

 

parameter in the F-Link 

Parameters 

tab.  

Different fire alarm indication: 

YES/NO* - 

Determines whether the siren 

will differentiate  between acoustic indications  of fire and standard alarms. 

The indication of an acoustic fire alarm is identical to smoke detectors with 

internal sirens – fast beeping. 

Other acoustic indication from sections:  

Selection determines which 

sections will indicate other types of alarm via the detector. Indication for 

all sections is enabled by default. 

When controlled by a section: 

YES / NO* 

- If enabled, the siren beeps 

1x after setting, 2x after unsetting and 3x times when unsetting after  

an alarm. It only does so for selected sections. 

During warning: YES / NO* 

- when enabled, the siren reacts with three 

beeps  to  the  inability to set the system,  unsuccessful setting and 

unsetting with an active alarm memory. 

Entry delay: 

YES / NO* - 

if enabled, the siren indicates the entrance 

delays of the selected sections.  

Exit delay when partially set: 

YES / NO* 

if enabled, the siren indicates 

the exit delays of the selected sections when the system is set partially. 

This option  is  available only when the  entrance delay of  fully set 

sections is enabled.

 

Exit delay when fully set:  YES 

/ NO* 

if enabled, the siren  indicates  

the exit delays of the fully set selected section. 

Level of volume of supplementary acoustic indication:  Standard*, 

Increased, By button, Programmable

 

– Applies only to other acoustic 

indication and the acoustic indication of PG outputs. It has no influence 

on the volume of alarm indication. If the “By button” option is selected, 

the  volume  can be changed by a user by pressing the lower part  

of the siren for 3 seconds (when the system is out of Service mode) – 

the change of volume  is confirmed by  a beep and  in the volume  

of the new selected volume. 

The “Programmable” option displays time sliders which set a period 

of time to switch between the standard and increased loudness during 

the day.  

 

The Signalling PG tab: 
LED indicates sounding PG output: 

If enabled, acoustic indication  

is triggered by an active PG output is continuously indicated by LED

.  

Sound indication can be set for each PG output:

 

Slow beeping 

-  beeps  1x  per second (as long as the PG output  

is active). 

Quick beeping

  –  beeps  2x  per second (as long as the PG output  

is active). 

1x ON/2x OFF 

– beeps 1x when the PG is activated, beeps 2x  when 

the PG is deactivated. 

20 sec of beeping – 

beeps continuously for 20 secs when a PG output 

is activated. 

Melodies 1 to 4 

– available doorbell melodies

 

System reaction to pressing  

a siren button 

By default, pressing the siren button during an alarm mutes the siren 

and concurrently confirms a person’s presence in the building  

(the control panel sends a report).  It is possible to change the siren 

button settings in the 

Devices

  window of the F-Link software to trigger  

a different reaction, for example a Panic alarm. 

 

The siren power supply can only be installed 

by a person with an adequate electro-

technical qualification. 

 

WARNING: This device is directly connected 