background image

DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377   Fax: +44 (0)1249 443388  E-mail: [email protected]    

www.danlers.co.uk

Company Registered Number 2570169   VAT Registration Number 543 5491 38

01/03/18 

INS369 CBU-HBWD IP66

CBU-HBWD IP66

IP66 Rated Ceiling High Bay (Wide) Passive 
Infra Red (PIR) Occupancy Detector & Photocell

Input: 220-240 Vac  50Hz                              

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: CBU-HBWD IP66 is only compatible to work with CASAMBI enable equipment

This CBU-HBWD IP66 High Bay 

(Narrow Detection) Lighting Control 

has an IP66 rated weatherproof 

enclosure and can be ceiling 

mounted. Confi gurable via the free 

to download Casambi APP on 

Google Play or Apple APP Store.

INSTALLATION

To be installed by a competent person with 

reference to BS 7671 or equivalent local standards. 

If in doubt consult a qualifi ed electrician.

•  Plan where the CBU-HBWD IP66 is to be 

located (see diagram 1). Switch off supply and 

check for hidden cables and pipes. 

•  Remove the front cover by quarter turning the 

four quick release fasteners to the ‘0’ position 

(see diagram 4 overleaf). 

•  Mount the back section of the mounting box in 

the required location via the 4 corner holes.

•  Thread mains cable carefully through the 

required membrane entry point.

•  Unclip the internal back plate. Remove the 

required knock out if replacing the optional 

internal back plate. 

•  Thread mains cable into the unit. The CBU-

HBWD IP66 should be connected as shown in 

diagram 2:

  L - Live in.   N - Neutral in.
•  Reclip the internal back plate if required.
•  Replace the front cover ensuring the quick 

release fasteners are secured in the ‘1’ position.

OPERATION

To check the operation of the CBU-HBWD IP66:
•  Turn on the supply then after 20 seconds if the 

sensor has recognised movement of a person 

within its zone of detection the integral red LED 

on CBU-HBWD IP66 will stay illuminated for 4 

seconds before the red LED turns off.

•  Thereafter, every time movement is detected by 

CBU-HBWD IP66 the integral red LED will stay 

illuminated for 4 seconds. 

The control also features adjustable time out (time 

lag) control and daylight threshold control which 

are confi gured by the Casambi APP.

PRECAUTIONS

•  Do not place the CBU-HBWD IP66 near heat 

sources, fans or in ventilated ceiling voids.

•  CBU-HBWD IP66 can be wired in parallel 

(sharing the same Live and Neutral).

•  Do not place close to, or positioned such 

that, any light source points directly into the 

CBU-HBWD IP66. 

•  Ensure wires and cables are securely held within 

the connection terminals.

•  The CBU-HBWD IP66 should be protected by a 

5 or 6 Ampere mcb or fuse.

• 

Disconnect the CBU-HBWD IP66 from the 

circuit before performing insulation testing 

of the wiring circuit.

DIAGRAM 1

TECHNICAL DETAILS

INPUT

Voltage:

220 - 240Vac

Frequency:

50Hz

Max. mains current:

0.05A

Standby current:

0.05A

RADIO TRANSCEIVER

Operating frequencies: 2.4... 2,483 GHz
Max. output power:

+4 dBm

LUX PARAMETERS

Range:

5 - 2000 lux

OPERATING CONDITIONS 

Note: The temperature difference between the 

detection target and the background must be 

at least 4 °C.
Max. case 

temperature:

+70 °C

Storage temperature:

-25... +75 °C

Max. relative humidity:

0... 80%, non cond.

CONNECTORS

Terminal block 

Wire size:

0.5mm

2

 - 2.5mm

2

 

solid or stranded

Wire strip length:

6-7mm

Tightening torque:

0,4 Nm/4 Kgf.cm

MECHANICAL DATA

Dimensions:

110mm x 110mm x 

73mm

Weight:

255g (unpacked)

Degree of protection:

IP66

Protection class:

Built-in Class 2

Material (casing)

Flame-retardant 

polycarbonate/ 

Polypropylene.

Finish / Colour

Matt /Grey (RAL 7035)

Protection class:

Built-in Class 2

CONFORMITY AND STANDARDS

EMC emission:

EN60669-2-1:2004 

inc. A12:2010

EMC immunity:

EN60669-2-1:2004 

inc. A12:2010

Safety:

EN60669-2-1:2004 

inc. A12:2010

Environment:

Complies with WEEE 

and RoHS directives

5 YEAR WARRANTY

CBU-HBWD IP66 comes with a 5 year  
warranty from the date of manufacture 
and is CE marked.

N

L

N

L

230Vac

5A or 6A MCB 

or fuse

L - Live in.  N - Neutral in.

Two neutral and two live terminals 

are available for easy ‘loop in’ and 

‘loop out’ connection. 

N

L

DIAGRAM 2

Suggested typical wiring

DIAGRAM 3

plan

side

110

110

73

Up to 

28m diameter

Mounting height 

up to 14m

Perspective view - 

ceiling mounted

Reviews: