NORDAC SK 200E Manual
70
Subject to technical alterations BU
0200
GB
Connection plan and parameterisation of SK CU4-POT, example
Frequency inverter
SK 2x5E-...
Contro
l termin
al bar
44
40
.
.
21
22
23
24
.
.
.
SK CU4-POT
Poten-
tiometer
0-10
R/0/L
Switch
L1 - L2/N - L3
115/230/400V
24V mains unit
SK CU4-24V-...
L1 - L2/N
115/230/400V
24V=
GND
10V=
AGND
0-10V
R
L
0-100%
1/3~
115/230/400V
+
PE
Control terminal bar
44 40 44 ... 11 14 12 B1
DIP switch settings:
DIP3 = off, DIP4 = on, DIP5 = off (Chapter 4.1.1)
or
Recommended
parameter setting, DIP1-8 = off:
P400 [07] = 1 P420 [02] = 2
P420 [01] = 1 P420 [03] = 26