5.8 Information
BU 0200 GB
Subject to technical alterations
137
Parameter
Setting value / Description / Note
Device
Supervisor
Paramter-
satz
P720
Actual torque current
-999.9 ... 999.9 A
Displays the actual calculated torque-developing output current (active current). Basis for
calculation are the motor data P201...P209 ... .
negative values = generator,
positive values = drive
P721
Actual field current
-999.9 ... 999.9 A
Displays the actual calculated field current (reactive current). Basis for calculation is the motor
data P201...P209 ... .
P722 Actual
voltage
0 ... 500 V
Displays the actual AC voltage supplied by the FI output.
P723
Actual voltage components Ud
0 ... 500 V
Displays the actual field voltage component.
P724
Actual voltage components Uq
0 ... 500 V
Displays the actual torque voltage component.
P725
Actual cos phi
0.00 ... 1.00
Displays the actual calculated cos
of the drive.
P726 Apparent
power
0.00 ... 99.99 kVA
Displays the actual calculated apparent power. Basis for calculation is the motor data
P201...P209 ... .
P727 Mechanical
power
-99.99 ... 99.99 kW
Displays the actual calculated effective power of the motor. Basis for calculation is the motor
data P201...P209 ... .
P728 Mains
voltage
0 ... 1,000 V
Displays the actual mains voltage at the FI input.
P729 Torque
-400 ... 400 %
Displays the actual calculated torque. Basis for calculation is the motor data P201...P209 ... .
P730 Field
0 ... 250 %
Displays the actual field in the motor as calculated by the inverter. Basis for calculation is the
motor data P201...P209 ... .
Содержание NORDAC SK 200E
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 35: ...2 Mounting and Installation BU 0200 GB Subject to technical alterations 35...
Страница 60: ...NORDAC SK 200E Manual 60 Subject to technical alterations BU 0200 GB...
Страница 151: ...5 9 Overview of Parameters User defined Settings BU 0200 GB Subject to technical alterations 151...