3.2 External Control Unit
BU 0200 GB
Subject to technical alterations
49
3.2.2
ParameterBox, SK PAR-3H
This option is for simple parameterisation and control of the frequency inverter, as well as the display of
current operating settings and states.
Up to 5 data sets can be stored and managed, stored and transferred with this device. This enables an
efficient start-up for serial applications.
NOTE:
In order to use the ParameterBox SK PAR-3H with the SK 200E, this must at least have
software 4.0 R3
installed.
Features of the ParameterBox
Illuminated, high resolution LCD graphics screen
Large-screen display of individual operating parameters
6 language display
Help text for error diagnosis
5 complete inverter data sets can be stored in the
memory, loaded and processed
Can be used for the simultaneous display of several
operating values
Standardisation of individual operating parameters to display specific system data
Direct control of a frequency inverter
Information from the ParameterBox
After plugging the ParameterBox onto the frequency inverter and switching on the mains for the first time,
there is initially an
enquiry as the menu language, German or English. The required language is
confirmed by pressing OK.
Then the ParameterBox automatically carried out a “bus scan”, during which the connected frequency
inverters are identified.
In the following display, the type of frequency inverter, its actual operating condition and the current status
can be seen.
After the inverter has been enabled, the display mode changes to the 3 current operate values (frequency,
voltage, current). The operating values displayed can be selected from a list of possible values (in the
>Display< / > Values< menu).
NOTE
The digital frequency setpoint (Jog frequency/minimum frequency) has a default setting of 0Hz.
To check whether the motor is working, a frequency setpoint must be entered with the
key or a jog frequency entered via the relevant menu level >Parameterise<, >Base
parameters< and the relevant parameter >Jog frequency< (P113).
Settings should only be made by qualified personnel, in strict compliance with the warning
and safety information.
ATTENTION:
The motor may start immediately after pressing the START key
!
Содержание NORDAC SK 200E
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 35: ...2 Mounting and Installation BU 0200 GB Subject to technical alterations 35...
Страница 60: ...NORDAC SK 200E Manual 60 Subject to technical alterations BU 0200 GB...
Страница 151: ...5 9 Overview of Parameters User defined Settings BU 0200 GB Subject to technical alterations 151...