5.9 Parameter overview, User settings
(P)
Depends on parameter set. These parameters can be set in various ways in the four parameter sets.
[xx]
Array parameter. A parameter can be set in various sub-groups.
S
Supervisor parameter, visibility depends on P003.
Parameter Nr.
[Array]
Name
Factory
setting
Super
visor
Setting after commissioning
P 1
P 2
P 3
P 4
OPERATING DISPLAYS (5.1)
P000 Operating
display
P001 Selection
display
0
P002 Factor
display
1.00
S
P003 Supervisor
code
1
1 = S parameters are hidden
4 = all parameters are visible
BASIC PARAMETERS (5.2)
P100
Parameter
set
0
S
P101
Copy parameter set
0
S
P102 (P)
Acceleration time [s]
2.0
P103 (P)
Deceleration time [s]
2.0
P104
(P)
Minimum
frequency
[Hz]
0.0
P105 (P)
Maximum frequency [Hz]
50.0
P106
(P)
Ramp
smoothing
[%] 0
S
P107 (P)
Brake reaction time [s]
0.00
P108
(P)
Disconnection
mode 1
S
P109 (P)
DC brake current [%]
100
S
P110 (P)
DC braking time on [s]
2.0
S
P111 (P)
P factor torque limit [%]
100
S
P112 (P)
Torque current limit [%]
401 (off)
S
P113
(P)
Jog
frequency
[Hz] 0.0
S
P114 (P)
Brake ventilation time [s]
0.00
S
P120 [01]
Option monitoring - Ext 1
S
P120 [02]
Option monitoring - Ext 2
S
P120 [03]
Option monitoring - Ext 3
S
P120 [04]
Option monitoring - Ext 4
S
MOTOR DATA / CHARACTERISTIC CURVE PARAMETERS (5.3)
P200 (P) Motor
list
0
P201 (P)
Nominal motor frequency [Hz]
50.0 *
S
P202 (P)
Nominal speed [rpm]
1385 *
S
P203 (P)
Nominal motor current [A]
4.8 *
S
P204 (P)
Nominal motor voltage [V]
230 *
S
P205 (P)
Nominal power [kW]
1.10 *
P206 (P)
Motor cos phi
0.78 *
S
Содержание NORDAC SK 200E
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 35: ...2 Mounting and Installation BU 0200 GB Subject to technical alterations 35...
Страница 60: ...NORDAC SK 200E Manual 60 Subject to technical alterations BU 0200 GB...
Страница 151: ...5 9 Overview of Parameters User defined Settings BU 0200 GB Subject to technical alterations 151...