Parameter
Setting value / Description / Note
Device
Supervisor
Paramter-
satz
P744 Configuration
0000 ... FFFF (hex)
This parameter displays the special devices integrated in the FI. Display is in hexadecimal code
(SimpleBox, Bus system).
The display is in plain text when the ParameterBox is used.
High byte:
Low byte:
00
hex
01
hex
02
hex
03
hex
No extension
Encoder
Posicon
---
00
hex
01
hex
02
hex
03
hex
Standard I/O
(SK 205E)
STO
(SK
215E)
AS-I
(SK
225E)
STO and AS-I
(SK 235E)
P747
Inverter voltage range
0 ... 2
Indicates the mains voltage range for which this device is specified.
0 =
100..0.120V
1 =
200..0.240V
2 =
380..0.480V
P748
System bus status
0000 ... FFFF (hex)
or
0 ... 65535 (dez)
Displays the system bus status.
Bit 0:
Bit 1:
Bit 2:
Bit 3 ... 5:
Bit 6:
Bit 7:
Bit 8:
Bit 9:
Bit 10:
24V Bus supply voltage
CANbus in "Bus Warning" status
CANbus in "Bus Off" status
vacant
The protocol of the CAN module is 0 = CAN / 1 = CANopen
vacant
"Bootsup Message" sent
CANopen NMT State
CANopen NMT State
CANopen NMT State Bit 10 Bit 9
Stopped
Pre-Operational
Operational
0
0
1
0
1
0
P749 DIP
switch
status
0000 ... 00FF (hex)
or
0 ... 255 (dez)
This setting displays the actual setting of the FI DIP switches (Section 3 / 4.1)
Bit 0:
Bit 1:
Bit 2:
Bit 3:
Bit 4:
Bit 5:
Bit 6:
Bit 7:
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
DIP switch 5
DIP switch 6
DIP switch 7
DIP switch 8
Содержание NORDAC SK 200E
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 35: ...2 Mounting and Installation BU 0200 GB Subject to technical alterations 35...
Страница 60: ...NORDAC SK 200E Manual 60 Subject to technical alterations BU 0200 GB...
Страница 151: ...5 9 Overview of Parameters User defined Settings BU 0200 GB Subject to technical alterations 151...