NORDAC SK 200E Manual
54
Subject to technical alterations BU
0200
GB
Menu structure level
Screen layout during parameterisation
If the setting of a parameter is changed, then the value flashes until it is confirmed with the OK key. In order
to retain the default settings for the parameter being edited, both VALUE keys must be pressed
simultaneously. Even in this case, the setting must be confirmed with the OK key in order for the change to
be saved.
If the change is not to be saved, then pressing one of the SELECTION keys will call up the previously stored
value and pressing a SELECTION key again will exit the parameter.
P102
PS1
3
Acceleration time
2.90
s
ONLINE
FI
P1
E ready
NOTE:
The lowest line in the display is used to display the current status of the box and the frequency
inverter being controlled.
NOTE:
Some parameters (e.g. P502) have additional array levels, in which further settings can be
made. The required array level must first be selected (see parameterisation, Section 5) and
confirmed with OK. The required parameter setting can now be made.
P502
PS1
[01]
3
Master function value
Off
ONLINE
FI
P1
E ready
Parameter set to be edited
Parameter to be edited (No.)
Parameter to be
edited (text)
Current parameter
value
Current
ParameterBox
status
Selected
control medium
Active parameter set in
control object
Status of control object
Array level of
selected parameter,
e.g. [01], [02], [03]...
Содержание NORDAC SK 200E
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 35: ...2 Mounting and Installation BU 0200 GB Subject to technical alterations 35...
Страница 60: ...NORDAC SK 200E Manual 60 Subject to technical alterations BU 0200 GB...
Страница 151: ...5 9 Overview of Parameters User defined Settings BU 0200 GB Subject to technical alterations 151...